Wiki Article

Network PA System for medium to large-scale tasks

Intro

The XC-9000 system is a fully electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP procedure, the system guarantees the reliable and proper transmission of all data packages. Not only can it utilize existing computer networks, such as LANs or the Internet, to transmit broadcast signals, yet likewise it can also be released on a devoted broadcasting network.

The server is extremely effective. Even when linked with a a great deal of terminals, it can simultaneously handle the same task smoothly. A single-server system can support up to 3000 terminals and allows for web server plunging. There are no restrictions on the concurrent program networks, accomplishing true full digital broadcasting .

System Qualities

Versatile PA System Layout

The PA system design is basic, including solution administration software application, network microphones, network amplifiers, network audio speakers, and other devices.All tools is linked through the TCP/IP intranet method, enabling flexible arrangement and simple monitoring of the system, with complimentary control over broadcast content, network tools, and regions via the network.

Ip Paging MicrophoneIp Paging Microphone
Comprehensive Audio Monitoring

The audio administration software consists of integrated functions for developing program plans, adaptable zoning, and pre-scheduled broadcasts.It supports 24-hour shows, enabling transforming setups during throughout the day

Versatile Audio Resource Support

The system sustains numerous types of audio resources for sending alerts like live speech and BGM playback. Sound resources can come from electronic music apps, CD/DVD players, microphones, and so on. In enhancement, the system gives diverse functions of sustaining various broadcasting functions such as scheduled broadcasting, zoned broadcasting, and emergency broadcasting.

Fire Alarm System System Integration

The system has an emergency alarm feature and can be integrated right into a smoke alarm system. When the alarm main system obtains the worrying signals, the wire will transmit the signal to tools, which activates the XC-9000, sending signals to audio speakers

Users might select to preset setups to turn on full-area or zoned alarm systems in emergencies. The alarm system voices been available in numerous types and might be modified satisfying needs. For example, individuals can transform language setups, upload and modify their audio sources according to exact requirements, such as intruding alarms, fire alarms or air aid alarms, etc



Emergency Alarm System Combination

The system has an emergency alarm function and can be integrated right into a fire alarm system. When the alarm system main device obtains the startling signals, the cable television will transmit the signal to devices, which triggers the XC-9000, sending out signals to audio speakers

Individuals can pick to pre-programmed setups to trigger full-area or zoned alarms in emergency situations. The alarm system voices been available in several kinds and can be modified dealing with requirements. For instance, customers can alter language setups, upload and modify their audio resources according to specific needs, such as intruding alarm systems, emergency alarm or air aid alarm systems, and so on



Application Control for System Procedures

The system allows mobile app login and use, permitting customers to launch programs and other procedures to licensed terminals through the server software application, ensuring a streamlined and convenient experience.

Integrated SIP Compatibility

The system not only permits SIP phones to log in, yet likewise can be attached to third-party SIP web server or IPPBX, which develops a completely incorporated and compatible interaction system through smooth combination right into existing systems.

Open SDK

When huge job like clever park takes place, the system gives an open SDK integrated right into third-party application systems - IP PA System

System Facilities

Main Features

Arranged Playback

The system has the ability to automatically transmit according to the scheduled jobs as long as customers submit the audio apply for each time period of the day to the web server and produce a playback schedule.

Area Broadcasting

The system can randomly divide a couple of network tools right into different zones to play defined audio programs or send announcements to any type of assigned location. The volume of each gadget can be from another location changed.

Real-time Broadcasting

The system can transmit and capture radio programs or other outside audio resources in real-time, and at the same time transmitted them in sync.

Emergency Alarm Assimilation

The system can be incorporated with the emergency alarm system for control. When a fire alarm signal is activated, it immediately turns on the emergency broadcast feature and sustains surrounding flooring alarms. It likewise permits manual emergency situation broadcasting by clicking a solitary button.

SIP Phone Combination

The system can be integrated with SIP servers, enabling online speech of voice broadcasting via SIP phones to send news anytime and anywhere.

CCTV Combination

The electronic gadgets such as IP POE Audio speakers adopts the international common ONVIF protocol, which allows their voices to be relayed using VMS platforms. The terminals can also be incorporated with CCTV systems for integrated broadcast.

Main Products

Sound Monitoring Software Program XC-9000

B/S style, supports cross-platform applications. Covers conventional broadcasting system works, enabling partition monitoring. Unified monitoring of terminals within the system, seeing work status, and set quantity change, etc. Supports building multi-level web server designs, deploying management according to user geographical areas. Supplies SDK advancement packages for second advancement and combination with various other system platforms.

Network Paging Console XC-9038N

Power: DC12V/1.5 A. Show: 4-inch touchscreen, resolution 480 * 480. Communication Methods: TCP/IP, UDP, SIP. Signal-to-Noise Ratio: > 80dB. Frequency Reaction: 100Hz~ 16KHz. Operating Temperature: 0~ 45 ℃. Measurements: 144 * 144 * 34.1 mm.

Network Paging Console XC-9037N

Power Supply: DC12V/1.5 A. Present: 4-inch touchscreen, resolution 480 * 480. Communication Protocols: TCP/IP, UDP, SIP. Signal-to-Noise Ratio: > 80dB. Regularity Feedback: 100Hz~ 16KHz. Running Temperature: 0~ 45 ℃. Measurements: 144 * 144 * 34.1 mm.

Network Horn Audio Speaker GEN-6391A03

Power Supply: DC24V/2.7 A or POE. Interaction Procedure: TCP/IP, UDP, SIP, ONVIF. Signal-to-Noise Proportion: > 80dB. Regularity Action: 100Hz~ 18KHz. Intercom: Supported, Built-in Microphone. Running Temperature: -20~ 50 ℃. Measurements: 283.1 * 224.3 * 269mm.

Network Ceiling Speaker GEN-6211A03

Power Supply: DC 24V/1A or POE. Interaction Procedures: TCP/IP, UDP, SIP, ONVIF. Signal-to-Noise Proportion: > 80dB. Frequency Response: 100Hz~ 18KHz. Running Temperature level: -20 to 50 ° C. Capacities: φ213 x 165mm.

Network Wall Mount Audio Speaker GEN-6011A03

Power Supply: DC24V/1A or POE. Communication Procedure: TCP/IP, UDP, SIP, ONVIF. Signal-to-Noise Ratio: > 80dB. Regularity Reaction: 100Hz~ 18KHz. Running Temperature: -20~ 50 ℃. Measurements: 193x151.5 x292mm.

Network Column Speaker GEN-6191A03


Power Supply: DC24V/1A or POE. Interaction Protocol: TCP/IP, UDP, SIP. Signal-to-Noise Proportion: > 90dB. Regularity Reaction: 45Hz~ 18KHz. Running Temperature: -10~ 55 ℃. Dimensions: 296x140x130mm.

Network Audio Bridge GEN-3101A01

Power Supply: POE. Interaction Procedure: TCP/IP, UDP, SIP. Signal-to-Noise Proportion: > 85dB. Regularity Reaction: 50Hz~ 20KHz. Running Temperature: -10~ 55 ℃. Measurements: 126x66x27mm.

Network Digital Amplifier XC-9508P

Power Supply: AC100V~ 240V, 50/60Hz. Power: 130W, 260W, 360W, 500W. Interaction Protocol: TCP/IP, UDP, SIP. Signal-to-Noise Proportion: > 80dB. Regularity Response: 60Hz~ 18KHz. Operating Temperature level: -10~ 50 ℃. Measurements: 440x300x44mm.

Zone Mixing Digital Amplifier NBS-2301

Power Supply : AIR CONDITIONER 220V, 50Hz. Power : 130W , 260W , 360W , 550W , 700W. Communication Procedure : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP. Signal-to-Noise Proportion :. Mic Input 01: ≥ 65dB,. Mic Input 02/03: ≥ 80dB,. Aux Input 01/02: ≥ 82dB. Frequency Reaction :. Mic Input 01: 80Hz~ 14kHz. Mic Input 02/03: 60Hz~ 16kHz. Aux Input 01/02: 60Hz~ 16kHz. Running Temperature level :. 10 ℃~ +50 ℃ (14 ℉~ 122 ℉) Measurements : 483x430x88mm.

IP User Interface Unit NAC-5003

Power Supply: AC100V~ 240V, 50/60Hz. Communication Procedure: TCP/IP, UDP. User interfaces: 1 Ethernet port, 32 alarm system inputs, 8 alarm system outputs. Operating Temperature level: -10~ 50 ℃. Measurements: 483x259x44mm.

Remedy For School



Versatile Zoning Broadcast:

The fully network terminals can understand versatile zoning alternatives, permitting for broadcasting alerts to individual terminals or various zones ( devices).

College Bell System:

It gives college bell system at the beginning/ending of the class - IP Speaker. Several scenarios can be made, consisting of different set up broadcast jobs according to summer/winter timetable

Emergency Alarm Integration

It supports assimilation with fire alarm systems, permitting emergency alarm signals to be integrated into the PA system.

Class Audio Boosting

Terminals support everyday applications in classroom scenes. They can be connected to projectors or interactive white boards for audio amplification.

Ip Paging MicrophoneIp Pa System

Smart Road Lamp/Security Pole

Assistance SIP Procedure:

Integrated SIP protocol for seamless assimilation with network communication systems.

VMS Operatings Systems Combination:

Integrated ONVIF method for combination with VMS platforms.

Third-Party Assimilation:

Constructed In HTTP API for integration with 3rd party platforms.

Voice Alarm System Activating:

Integrated in alarm system input interface for setting off voice alarm systems with video cameras.

Remedy For Resort

Zone Control by Floor:

The system supplies full network settings, separating zones depending on different floors and control over each area individually.

Fire Alarm Integration:

The system can be incorporated with smoke alarm system, enabling combination of emergency alarm signals right into the broadcasting system.

Scheduled Broadcasting:

It supports programmable set up broadcasting, allowing versatile plans according to numerous needs.

Emergency Broadcasting:

It supports emergency situation broadcasting for the entire area, SPON Communications allowing one-click emergency situation interaction.

Remedy For Factory

Zone Broadcasting:

It enables relaying to any kind of area, ensuring no interference in between different locations.

Alarm system Triggering:

Terminals have various type of user interfaces, making it possible for to trigger alarms when connected with video cameras.

All Network Instruments:

Implementation of totally network gadgets significantly minimizes the problem of operating such as examining devices on harmful sites, and thus securing people and residential or commercial property.

The release of all network tools substantially minimizes the trouble of procedure and upkeep administration

Integrated SIP Phones:

The system can be integrated with SIP phone and broadcast notifications using SIP phones at any moment and anywhere. Two-way audio talkback in between SIP phones and IP POE Speakers makes it easy for checking devices sitting in workplace or various other work environments.

The XC-9000 system is a completely digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP procedure, the system makes sure the appropriate and efficient transmission of all data packages. The system sustains various kinds of audio resources for sending alerts like online speech and BGM playback. In addition, the system provides varied functions of sustaining different broadcasting features such as scheduled broadcasting, zoned broadcasting, and emergency broadcasting.

The system can be integrated with the fire alarm system for control.

Report this wiki page